DOUBLE SMART MODULE is designed for on/off remotely controlling electrical devices (door locks, door openers, etc). The output contact is voltage free (dry contact) giving the possibility to use different power supply loads.
Powered up using:
110 - 240 [V] AC with a maximum current: 9.5 [A] (resistive load) => 2280 [W]
24 - 30 [V] DC with a maximum current: 9.5 [A] (resistive load) => 228 [W]
It can control motors that have direction controlled by only one wire.
Frequently used at: Heating systems on/off control, Gates and garage doors, conventional incandescent lights.
Our engineers will offer you the best solutions for your projects
Refunds are processed within 1-2 days
Using latest standards in security policies
- Power supply must be:
100 - 240 VAC and requires NEUTRAL Wire (NUL);
OR
24 - 30 VDC
- A Z-Wave Hub is required!
- Designed to be installed in standard wall switch boxes or anywhere else it is necessary to control electric devices. Allows us to control the connected devices either via Z-Wave or via mechanical switch.
- It can control 2 circuits with loads that doesn't exceed a total power of 2280 W (VAC) or 228 W (VDC).
- Do not connect loads greater than those recommended!
- Do not connect types of load other than resistive or incandescent!
Smart Module is a small size module created by Fibaro, that can be integrated in standard wall switch boxes. It allows us to remotely control connected devices using the Z-Wave Network (a Z-Wave Hub is required).
Notes for the diagrams:
S1 - terminal for 1st switch;
S2 - terminal for 2nd switch;
L - terminal for Live wire (100 - 240 VAC) or - (for VDC);
IN - terminal for Live wire (100 - 240 VAC) or - (for VDC);
Q1 - output for 1st circuit;
Q2 - output for 2nd circuit;
N - terminal for Neutral wire (for AC) or + (for VDC);
B - service button (used to add/remove the device from the Z-Wave network).
It can be fit into standard wall switch boxes or anywhere else it is necessary to control electric devices.
Power supply |
110 - 240 VAC. ~ 50/60Hz 24 - 30 VDC |
Current |
Maximum 6 A on each channel (Q) - resistive or incandescent loads Maximum 9.5 A total when both channels (Q) are used |
Overcurrent protection |
External 6 A circuit breaker required - if there is only 1 channel (Q) used External 10 A circuit breaker required - if there are both channels (Q) used |
Active element |
micro-gap relay switch μ |
Operating temperature |
0 - 35 °C |
Technology |
868.42 MHz Z-Wave Plus (500 series) |
Dimensions (L x W x H) [mm] |
42.5 x 38.25 x 20.3 |
Range |
- up to 50 m outdoors - up to 30 m indoors depending on terrain and building materials |
Security |
AES - 128 Encryption |
You might also like